Optimal Capacitor Bank Installation for Power Factor Correction at Jemursari Prapen Pump House, Surabaya
Abstract
This study aims to analyze and evaluate power factor correction (cos φ) in the electrical installation of the Prapen pump house in Surabaya City, with the goal of reducing penalty charges incurred from excessive reactive power consumption (kVArh) imposed by the national utility company, PLN. Based on initial data obtained from measurements and electricity usage records, the pump house has an average power factor of 0.70 with an active power load of 707.95 kW. This low power factor results in high reactive power consumption and leads to significant monthly penalty costs. On average, the facility pays approximately IDR 31 million per month in penalties, which becomes a substantial operational expense. To address this issue, a simulation and reactive power compensation analysis were conducted using ETAP version 19.0.1 software. The simulation proposed the installation of capacitor banks to supply capacitive reactive power and improve the overall power factor closer to the ideal value. The target power factor was set at 0.95, in accordance with PLN regulations, in order to eliminate or minimize penalties. The simulation results indicate that the required reactive power compensation is approximately 488.485 kVAr. To meet this requirement, capacitor banks with a total capacitance of around 9507.8 μF need to be installed. The installation of these capacitor banks is expected to effectively improve the power factor, reduce power losses, and result in significant cost savings for the operation of the Prapen pump house in Surabaya City.
Downloads
Downloads
Published
Issue
Section
License
Authors who publish with Elsains: Jurnal Elektro agree to the following terms:
- Authors transfer the copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.. that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access)