Optimal Capacitor Bank Installation for Power Factor Correction at Jemursari Prapen Pump House, Surabaya

Authors

  • Reza Sarwo Widagdo Universitas 17 Agustus 1945 Surabaya, Indonesia
  • Puji Slamet Universitas 17 Agustus 1945 Surabaya, Indonesia
  • Aris Heri Andriawan Universitas 17 Agustus 1945 Surabaya, Indonesia https://orcid.org/0000-0002-1879-8431
  • Izzah Aula Wardah Universitas 17 Agustus 1945 Surabaya, Indonesia https://orcid.org/0000-0002-7520-8450
  • Imam Suri Tauladan Universitas Riau, Indonesia
  • Teguh Bayu Saputra Universitas 17 Agustus 1945 Surabaya, Indonesia

Abstract

This study aims to analyze and evaluate power factor correction (cos φ) in the electrical installation of the Prapen pump house in Surabaya City, with the goal of reducing penalty charges incurred from excessive reactive power consumption (kVArh) imposed by the national utility company, PLN. Based on initial data obtained from measurements and electricity usage records, the pump house has an average power factor of 0.70 with an active power load of 707.95 kW. This low power factor results in high reactive power consumption and leads to significant monthly penalty costs. On average, the facility pays approximately IDR 31 million per month in penalties, which becomes a substantial operational expense. To address this issue, a simulation and reactive power compensation analysis were conducted using ETAP version 19.0.1 software. The simulation proposed the installation of capacitor banks to supply capacitive reactive power and improve the overall power factor closer to the ideal value. The target power factor was set at 0.95, in accordance with PLN regulations, in order to eliminate or minimize penalties. The simulation results indicate that the required reactive power compensation is approximately 488.485 kVAr. To meet this requirement, capacitor banks with a total capacitance of around 9507.8 μF need to be installed. The installation of these capacitor banks is expected to effectively improve the power factor, reduce power losses, and result in significant cost savings for the operation of the Prapen pump house in Surabaya City.

Downloads

Download data is not yet available.

Author Biographies

Reza Sarwo Widagdo, Universitas 17 Agustus 1945 Surabaya, Indonesia

Department of Electrical Engineering, Universitas 17 Agustus 1945 Surabaya, Indonesia

Puji Slamet, Universitas 17 Agustus 1945 Surabaya, Indonesia

Department of Electrical Engineering, Universitas 17 Agustus 1945 Surabaya, Indonesia

Aris Heri Andriawan, Universitas 17 Agustus 1945 Surabaya, Indonesia

Department of Electrical Engineering, Universitas 17 Agustus 1945 Surabaya, Indonesia

Izzah Aula Wardah, Universitas 17 Agustus 1945 Surabaya, Indonesia

Department of Electrical Engineering, Universitas 17 Agustus 1945 Surabaya, Indonesia

Imam Suri Tauladan, Universitas Riau, Indonesia

Department of Electrical Engineering, University of Riau, Indonesia

Teguh Bayu Saputra, Universitas 17 Agustus 1945 Surabaya, Indonesia

Department of Electrical Engineering, Universitas 17 Agustus 1945 Surabaya, Indonesia

Downloads

Published

2026-07-01

Issue

Section

Articles